Gateway setup
Connect over Bluetooth to configure sensors, interfaces and NMEA2000 output, and to recover session logs.
This browser does not support Web Bluetooth. Use Chrome or Edge, over HTTPS.
Health
Device
- Model
- —
- Hardware
- —
- Firmware
- —
- Serial number
- —
Radio
- Sensors in range
- —
- Configured sensors
- —
Actions
Updates are fetched by the gateway itself, so it needs a working network connection. The firmware reboots into the new image when it finishes.
Sensor
Calibration curve
Output across the 0–6.6 V input range. The gateway converts the ADC reading to voltage first, then applies value = volts × mul ÷ div + off⁄10000.
Outputs
Derived from the NMEA2000 station by the gateway; not set directly.
Digital output trip
Trips when the value is at or above the high threshold, or at or below the low one. Leave a threshold blank for no limit on that side. Takes effect after the next reboot.
Select a sensor, or add one.
System configuration
NMEA2000 output
1–240. The device will claim another if this one is taken.
How often each sensor is transmitted. 100–1000 ms.
Minimum gap forced between transmissions, to avoid flooding a busy backbone.
MQTT
Takes effect after a reboot
Include scheme and port. mqtts:// uses TLS and prefers the provisioned client certificate.
0 publishes on event.
Only used when no client certificate is provisioned. The stored password is never shown — leave blank to keep it.
Session logging
Master switch for the logging subsystem — takes effect after a reboot. Which sensors are logged is chosen per sensor, via the Sensors tab. Recorded sessions are recovered from the Logs tab.
Digital output
The output pin asserts when any sensor with an trigger enabled breaches its thresholds — the trigger is set per sensor. The engine reads its sensor list at boot, so a newly enabled trigger takes effect after the next reboot.
Licence
- Gateway ID
- —
- Expires
- —
- Key ID
- —
- Tier word
- —
The gateway can hold several keys. What you see here is the combined result: every feature any valid key grants, and the soonest expiry among them.
Takes the cyclops://license/… link.
Adding one does not replace the keys already held.
Dock tune
The target loads and tolerance bands the Dock Tune page displays.
Not read yet.
Changing these settings needs a key granting Change dock tune. The gateway refuses the write without one.
Status
unknownNot read yet.
Connect to WiFi
The gateway starts connecting as soon as the password arrives.
Session
| Sensor | Minimum | Maximum |
|---|
Load sessions, then pick one to chart.